Output data:
This system has two types of output. The first type is magnetic field output. It can send the amount of magnetic field in three directions to the output, (Heading, Pitch, Roll).
The second type, is the output angles. It sends an output in three angles.
Changing between these outputs is done with the following commands:
For the output of the magnetic field. *M
For the output of angles. *H
Output, Baud Rate
The output of the unit is 9600 and 4800, which could be changed by Baud Rate.
The following commands are performed:
For 9600 #Bau=9600
For 4800 #Bau=4800
After entering the commands to mention Baud Rate, it is necessary to mention that in order to be changed, the set must be turned off once.